ixxat

Posts Tagged ‘Module’

Feb
9
2010

IEM Implements Major Industrial Ethernet Protocols

Industrial Ethernet Module VideoSee how IXXAT’s Industrial Ethernet Module provides OEMs with a single hardware solution for multiple Industrial Ethernet protocols.

This video demonstrates how OEMs can utilize IXXAT’s Industrial Ethernet Module (IEM) to support multiple Industrial Ethernet protocols with a single hardware platform. Via SPI or Parallel-Bus your device will interface to the IEM and have access to EtherCAT, EtherNet/IP, PROFINET RT, POWERLINK, SERCOS III and Modbus/TCP networks. You will see how a simple IO board can communicate with both an Ethernet/IP network and an Ethernet POWERLINK by simply swapping the EtherNet/IP configured IEM for a POWERLINK configured IEM. The firmware inside the application CPU can support all of these protocols at once, and allows the OEM to quickly reach end users within many different markets.

Click here for more information about the Industrial Ethernet Module. North American customers please call 603-471-0800 x101 (for other countries +49-751-56146-0)

See the video…

Sep
25
2009

Industrial Ethernet Module with integrated Switch

IP Switch for Industrial Ethernet ModuleIXXAT’s FPGA based Industrial Ethernet Module (IEM) now integrates a high-capacity Switch-IP which enables customers to implement powerful and economic line topologies.

The IEM implements a cost efficient and flexible solution to adapt to various Industrial Ethernet technologies. The IEM is based on a powerful Altera Cyclone III FPGA which includes, besides an integrated 32-bit CPU, PHYs, magnetic modules and RJ45 jacks, the new 3-port switch IP for Profinet, EtherNet/IP and Modbus-TCP.


read more…

Jul
30
2009

Industrial Ethernet Module – POWERLINK Certified

POWERLINK Certified LogoConformance of the Industrial Ethernet Module (IEM) as part of the POWERLINK Starterkit now approved.

As one of the first devices, the IXXAT POWERLINK Starterkit Controlled Node (CN)
receives the official certificate of the EPSG POWERLINK Conformance Test. The Starterkit consists of an IXXAT Industrial Ethernet Module, a carrier board, a CPU module as well as a demo application. The IEM, as base hardware for different real-time Ethernet protocols, is based on the IXXAT POWERLINK stack, in the protocol variant for POWERLINK, and comes with an integrated Ethernet hub for the 2-port network connection.


read more…

Mai
25
2009

Implementation of Industrial Ethernet

Industrial Ethernet on FPGAsBy Christian Schlegel, IXXAT Automation GmbH

Today, the industrial automation market for Ethernet-based communication is increasing in demand. As with classical field busses, several protocol standards are available for Industrial Ethernet, which have to be supported by device manufacturers. Since these different Ethernet standards vary in their hardware and software requirements, a specific protocol solution for their integration into a device is required.

Despite the efforts of IAONA to find a common solution for industrial communication over Ethernet, disparate protocols emerged that were sponsored and promoted by a number of classic field bus suppliers. Eleven concepts to achieve Ethernet relevant for industrial communication are currently standardized within IEC 61158. Similar to the so-called “field bus wars” in the eighties, in the end, some of the eleven Industrial Ethernet solutions will be accepted in the market.

… read more

Feb
1
2009

EtherNet/IP Products

EtherNet/IP SoftwareIXXAT is distributor for the EtherNet/IP products from Pyramid Solutions

IXXAT, a well known provider of products and services for the industrial communication, now distributes the EtherNet/IP protocol software and tools from Pyramid Solutions, which are conforming to the ODVA specifications, worldwide.At this, IXXAT uses the EtherNet/IP software from Pyramid already successfully on its Industrial Ethernet Module.


read more…

Jan
5
2009

Powerlink with redundant Managing Nodes

Category: POWERLINK, Products

Powerlink with redundant Managing NodesPowerlink with redundant Managing Nodes according to the specification V 1.1.0 and WDS 302-A

A major safety feature for industrial communication is the continuous system availability, even if failures in essential components occur, e.g. in the communication master or in network connections (cables). To ensure a high system availability, the availability of the controller as well as of the network must be guaranteed.

For this reason, a highly available controller solution was considered for Powerlink at a very early stage, and was now specified in EPSG WDP 302 A and implemented by IXXAT.

read more…

Nov
10
2008

Update of the IXXAT analyzer software to version 2.6

Category: CAN, Products, Updates

Update of the IXXAT analyzer software to version 2.6IXXAT provides on it’s webpage a free patch file for the canAnalyser, canAnalyser-lite and MultibusAnalyser, enabling the customers to update their software to the latest version 2.6. The patch file requires an installed version 2.5.14.1488 of the software.

The new version 2.6 now also supports Windows Vista and comes with a .NET API according to the latest 2.0 standard. In addition, the new graphic module, which is included in the canAnalyser patch file, was revised and extended (not content of the canAnalyser-lite and MultibusAnalyser patch file).

Get the update …

Okt
14
2008

New Industrial Ethernet Module from IXXAT

Real-time Industrial Ethernet ModuleSupport of all important Industrial Ethernet Protocols.

At the upcoming SPS/IPC/DRIVES fair in Nuremberg, IXXAT will present the new Industrial Ethernet Module, which enables customers to easily connect their devices to networks based on an Industrial Ethernet standard.

The new Industrial Ethernet Module was designed from the ground up to support various protocol standards.
At this, a powerful Altera Cyclone III FPGA is used and low manufacturing costs for the module were a focus of attention.
As a result, the new Industrial Ethernet Module is more powerful, lower priced, smaller and can be used more flexible than its predecessor.

read more…

Jul
25
2008

New version of the IXXAT Powerlink stack available

Ethernet Powerlink Protocol Software StackConforms to the latest Powerlink
specification DS 1.0.0

The current version 1.04.05 of the Powerlink stack from IXXAT Automation GmbH provides the following features:

  • Node monitoring on Controlled Nodes (CNs) via object 0×1016
  • Support of all priority levels on Managing Nodes (MNs) for the allocation of the asynchronous communication channel
  • Support of all mandatory and many optional objects according to the Powerlink specification DS 1.0.0
  • Modification of the Node ID at run-time via the object dictionary
  • Tool for the stack configuration with GUI for scaling and generation of the IXXAT Powerlink software (especially static parameters and the object dictionary)
  • Switching between MN and CN functionality at run-time by changing the Node ID
  • Bug fixes and adaptations to increase the compatibility with implementations of other vendors


read more…

Okt
16
2007

Industrial Ethernet Module

blog_industrial_ethernet_mo.giffor PROFINET, EtherCAT, EtherNet/IP und Powerlink

With the proved “Industrial Ethernet Module” from IXXAT devices can quickly and cost-efficiently be adapted to various Industrial Ethernet technologies.


read more…