The CANio 500 enables the easy and quick connection of various analog and digital input and output signals to CAN or CANopen systems - whether in experimental setups, component test stands or vehicles.
A key feature of the device are the inputs and outputs for digital and analog signals, which can be configured very flexible. The device has each four analog inputs and outputs with a 12 bit resolution. The analog inputs are available with different voltage ranges, as well as with differential input circuits or current inputs. The output voltage range can be individually programmed in the working range of -10 V to +10 V for each analog output.
In addition, the device has four digital inputs and outputs. The output voltage range can be freely selected within a wide range, at this, the switching threshold of the inputs automatically adjusts according to the selected voltage range and the outputs are short circuit protected.
A special focus, during the development of the CANio 500, was the device operability within CANopen and also basic CAN systems. For this reason, the CANio 500 was designed as a self-starting CANopen slave, with all important parameters, such as Node-ID or sampling rates for the analog inputs, stored as default values on the device. This enables the device to start its operation directly after start up, without making any further settings, and allows due to this the operation in basic CAN systems.
The individual configuration of the CANio 500 for different applications can be done either by loading configuration data via a CANopen master or by sending configuration messages in a pure CAN network or offline via the free CANio 500 configuration tool. Configurations that have been created with the CANio 500 configuration tool can be saved as a project and on customer request preinstalled on ordered devices before delivery.
Technical Data
| CAN Protocols | CAN, CANopen |
| CAN Bus Interface | ISO 11898-2 |
| Galvanic Isolation | Yes (500 V DC) |
| Digital Inputs | 4 x + clamp 15 (between 0 ... 60 V, threshold at 50 %) |
| Digital Outputs | 4 x, max. 1 Ampere, output voltage free selectable, up to 34 V |
| Analog Inputs | 4 x, 12 Bit Res. +/- 5 V, or 0-10 V, or +/- 100 mA |
| Analog Outputs | 4 x, 12 Bit Res. +/- 5 V, or +/- 10 V, or 0-5 V, or 0-10 V, switchable via software |
| Further Interfaces | 2 LEDs Measurement of the power supply |
| Temperature range for operation | -40 °C to +70 °C |
| Power Supply | 6-32 V |
| Types of Plugs | CAN: D-SUB-9 I/O: D-SUB-HD15 |
| Protection Class | IP42 |
| Dimensions | 120 x 82 x 32 mm |
| CANio 500 Config-Tool | CANio500Config_1.0_Setup.exe [1,0 MB] |
| 1.01.0098.00000 | CANio 500 - Version with 0 to 10 V Analog Inputs |
| 1.01.0098.00001 | CANio 500 - Version with -5 to +5 V Analog Inputs |
| 1.01.0098.00002 | CANio 500 - Version with +/- 100 mA Analog Inputs |