Below is an overview of the frequently asked questions and answers about IXXAT PC CAN Interfaces. Select the interface you use:
USB Ethernet
For a correct functionality of CAN@net II the firewall has to be disabled or the packet filter has to be configured as following described: CAN@net II/VCI The CAN@netII/VCI uses the ports 15000/tcp and 15001/tcp. The PC must have access from all ports 1024-65535/tcp to the ports 15000/tcp and 15001/tcp of CAN@netII/VCI. The CAN@netII/VCI must have access form port 15000/tcp and 15001/tcp to all ports 1024-65535/tcp of the PC. CAN@net II/Generic The CAN@netII/Generic uses the port 19227/tcp. The PC must have access from all ports 1024-65535/tcp to the ports 19227/tcp of CAN@netII. The CAN@netII/Generic must have access form port 19227/tcp to all ports 1024-65535/tcp of the PC. CAN@net/VCI The CAN@Net uses the ports 19295/tcp and 19296/tcp. The PC must have access from all ports 1024-65535/tcp to the ports 19295/tcp and 19296/tcp of CAN@net. The CAN@net must have access form port 19295/tcp and 19296/tcp to all ports 1024-65535/tcp of the PC. CAN@net/Generic The CAN@net/Generic uses the port 19227/tcp. The PC must have access from all ports 1024-65535/tcp to the ports 19227/tcp of CAN@net.
The CAN@net/Generic must have access form port 19227/tcp to all ports 1024-65535/tcp of the PC.
1. Please check if you are using a correct type of the CAN@net II device. a) The CPU-LED of a CAN@netII/Generic flashes with 1 Hz green after power on. The CPU-LED of a CAN@netII/VCI flashes with 2 Hz green after power on. b) The CAN@netII/VCI does not have a Web-interface like a CAN@netII/Generic. The CAN@netII/Generic does not run as a VCI device with the Minimon. 2. Please check if the CAN@net II is configured correctly. Please clarify with your network administrator, which IP-address can be assigned to the CAN@net II.
Please note, if the CAN@netII is connected to the PC directly (without company network), you have to set a static IP address for the PC as well.
The CAN@net II and the PC have to be configured for the same network segment.
FORMULAIRE DE CONTACT
CONTACTEZ-NOUS
En utilisant notre site web, vous acceptez l’utilisation des cookies.