Plug-in CANopen Master/Slave module for SIMATIC® ET200S modular I/O system
The 1 SI CANopen module brings CANopen connectivity to the SIMATIC ET200S modular I/O system, enabling full integration between devices on a CANopen network and the ET200S. Furthermore, the addition of 1 SI CANopen module into the ET200S system allows a CANopen network to be seamlessly controlled from PROFIBUS and PROFINET.
With the 1 SI CANopen module HMS integrates its CANopen master technology with the SIMATIC architecture. The 1SI CANopen module enables easy integration of SIMATIC equipment into business segments where CANopen and other CAN based protocols are used today, also opening up the possibility for PROFIBUS or PROFINET controllers such as the S7 series of advanced controller devices to interact with CAN and CANopen fieldbus devices (gateways).
The 1 SI CANopen module is supported by all interface and CPU modules of the SIMATIC ET200S modular I/O sytem, with the exception of the Basic and Compact versions.
Getting Started Support We offer our customers support via phone, e-mail and Teamviewer in getting started the quickest way possible. This includes assistance in installation of the gateway, explaining the included programming examples, and giving an introduction to configuration.
Configuration Support Our experienced engineers can support you in configuring the gateway to fit into your application. This includes analyzing your system setup and requirements, adapting the configuration of the gateway, optimizing your PLC program and configuration. Communication is usually via e-mail, phone and Teamviewer. Optionally we can offer to come to your site and work with your engineers directly at your system.
Easy integration into the SIMATIC world is one of the most essential requirements when extending of the SIMATIC automation system with networked fieldbus equipment that is not based on either PROFIBUS or PROFINET. HMS has addressed this need enabling a seamless integration of the 1 SI CANopen module into either SIATIC STEP 7 or TIA Portal. Configuration of the connected CANopen network is intuitively performed with the optional Anybus Configuration Manager - CANopen.
Once the configuration is finalized, the CANopen network configuration may be uploaded to and stored in the PROFIBUS or PROFINET PLC or the ET200S I/O system CPU. If a 1 SI CANopen module has to be replaced, the previously stored configuration can be downloaded from the PLC to the new module, significantly reducing down-times in high availability applications. 1 SI CANopen modules may be replaced while the ET200S is powered.
With the transparent CAN functionality, the 1 SI CANopen module allows transmission of any CAN frame from the PLC regardless of the higher level CAN protocol and is capable of receiving a number of pre-defined CAN frames from the CAN network.
CAN 2.0A is the underlying protocol of many fieldbus protocols, CANopen being one of them. When the application disables CANopen functionality, it still retains access to this protocol.
HMS provides dedicated PLC function blocks for the transparent CAN functionality that give the designer of the PLC program the possibility to interpret and generate any CAN frame directly in the PLC program and thereby making it possible to implement customer specific protocols. Furthermore, it is also possible to connect devices that only support customer specific CAN protocols to a PROFIBUS or PROFINET network.
1 SI CANopen is designed to be plugged directly into an ET200S system rack slot. The module exchanges data via the backplane bus, which also supplies it with power. Four easy steps gets you up and running fast!