Repeaters

for CAN, CAN FD and
CAN-based higher layer protocols



Ixxat repeaters are used to establish a physical coupling of two or more segments of a CAN or CAN FD bus system. They can be used to implement tree or star topologies as well as for long drop lines. In addition, network segments can be electrically decoupled using a galvanically isolated repeater. 


CAN Repeaters
HMS_web-icon_High performance

Increase reliability

CAN and CAN FD repeaters increase your system reliability with almost no influence on the real-time behavior.

HMS_web-icon_diagnostic

For harsh environments

Ixxat repeaters decouple CAN or CAN FD segments galvanically up to 4 kV and are also available as variants with fiber optics.

HMS_web-icon_Finance

Save costs

Easier wiring and reduction of cables reduces the cost of your system.

CAN-CR220

ISO 11898-2 CAN repeater
with 4 kV galvanic isolation

The CAN-CR220 is used for the galvanic isolation of two segments of a CAN network and offers a very high galvanic isolation of 4 kV, allowing it be utilized in medical applications. One special feature of the Repeater is the automatic recognition and separation of a defective segment from the rest of the network so that the remaining network can continue working. After elimination of the defect, the segment is switched into the network again.

The galvanic isolation isolates the CAN segments from each other as well as from the power supply.

The CAN-CR220 is tested according DIN/EN 50178 (DIN VDE 0160: 1988-05 and DIN VDE 0160/A1: 1989-04).

Order codes: 1.01.0067.44400, 1.01.0067.44300

CAN Repeater - CAN-CR220

Features and Benefits

  • Line protection up to 4 kV
  • DIN/EN 50178 (DIN VDE 0160: 1988-05 and DIN VDE 0160/A1: 1989-04)
  • Cost savings due to simple wiring
  • Increased system reliability
  • Almost no influence on real-time behavior

Contents of delivery

  • CAN-CR220
  • Quick reference

Technical specifications

Display Transmit and defective segment (two duo LEDs), Power (one LED)
CAN bus interface ISO 11898-2 with CAN choke. Two Sub-D9 connectors. CAN termination resistors are integrated (switchable).
Baudrate Up to 1 Mbit/s
Delay 200 ns (corresponds ~40 m (~120ft.) bus length)
Power supply 9-32 V DC, 1.5 W typ., through terminals
Galvanic isolation CAN 1, CAN 2 and power supply are galvanic isolated against each other.

Isolation voltage 1.01.0067.44400
- 2.0 kV AC / 1 min
- 3.2 kV DC / 1 min
- 3.5 kV AC / 1 sec
- 4 kV DC / 1 sec 

Isolation voltage 1.01.0067.44300
- 3 kV AC / 3 min
- 3.75 kV AC / 1 min
- 4 kV DC / 1 min
- 4 kV AC / 1 sec
- 4 kV DC / 1 sec 
Certification CE, FCC
Temperature range  -20 ºC ... +70 ºC
Housing, size Plastic enclosure, 22.5 x 100 x 115 mm

Order number

1.01.0067.44400 CAN-CR220 (see technical data - galvanic isolation)
1.01.0067.44300 CAN-CR220 (see technical data - galvanic isolation)

This product is available to purchase from the following "online portals".

https://www.digikey.com/products/en?keywords=1.01.0067

Buying from an approved HMS Distributor
For volume pricing and access to first-line technical support and local language assistance, please contact your nearest HMS Distributor.

Find Distributor

Learn more about the repeaters and see how they work
Click to see application samples...

The lines coupled by the repeater are independent electric segments that can be optimally terminated in terms of signals. In this way topologies can be implemented that are not possible with a pure line of the bus due to electrical reflections. According to the transceiver output capacities, the division of a CAN / CAN FD system into several subsystems, connected via CAN / CAN FD repeaters, increases the maximum number of bus nodes. Using repeaters does not influence the real-time behavior of a system because in terms of transmission behavior it corresponds to a network that consists only of lines. In terms of signals, the repeater corresponds to a line with relevant delay time. Therefore, it cannot be used to extend a CAN / CAN FD system. However, using repeaters allows to increase the system dimensions indirectly, as shown in the sample.

Conventional bus structure
The distance between the two nodes furthest apart (1/6) is 220 meters test
       

Conventional bus structure

Extended structure with drop line
The distance between the two nodes furthest apart (1/4 or 4/6) is 150 meters
       

Extended structure with drop line

Contact us!

Need more information about the product or a quote? We are at your disposal...
Technical Services

Development services and OEM products

From brand-labelling, to HW/SW modification to completely custom designed products.

CAN Accessories

HMS offers special cables, plugs and termination resistors for the CAN and CAN FD products.

All you need for CAN

Under the Ixxat and Anybus brands, HMS offers over 200 different products for CAN, CAN FD and the CAN-based protocols.